NUMBER : N1TH061290U23
SUBJECT : Abend Internal Send Packet Error
DATE : 6/12/90
OS VERSION : 386 v3.0
REVISION :
SHELL VERSION :
PROBLEM : A customer go the following error on their NetWare 386
file server:
Abend: Internal send packet got an ECD that was already sent.
This error occured during heavy activity on the internet:
SOLUTION : In this particular situation the customer was using the
original Generic SCSI option with a DCB. The solution was to download the new
DCB.DSK from Netwire, reinitalize the drives and load the new driver.
COMMENTS (Optional) : This error mesage deals more with low level ipx and
could easily be caused by other problems also. However, in this case the
problem was caused by the old DCB disk driver.
YOUR NAME AND DEPT. :
(Check all that apply)
(X) This information was verified verbally.