home *** CD-ROM | disk | FTP | other *** search
/ Netware Super Library / Netware Super Library.iso / nov_info / fyi7 / 07101.dos < prev    next >
Text File  |  1990-07-10  |  977b  |  28 lines

  1.              NUMBER  : N1TH061290U23
  2.             SUBJECT  : Abend Internal Send Packet Error
  3.                DATE  : 6/12/90
  4.          OS VERSION  : 386 v3.0
  5.            REVISION  :
  6.       SHELL VERSION  :
  7.  
  8.             PROBLEM  :  A customer go the following error on their NetWare 386 
  9. file server:
  10.  
  11.   Abend: Internal send packet got an ECD that was already sent.
  12.  
  13. This error occured during heavy activity on the internet:
  14.  
  15.            SOLUTION  : In this particular situation the customer was using the 
  16. original Generic SCSI option with a DCB.  The solution was to download the new
  17. DCB.DSK from Netwire, reinitalize the drives and load the new driver.
  18.  
  19. COMMENTS (Optional)  : This error mesage deals more with low level ipx and 
  20. could easily be caused by other problems also. However, in this case the 
  21. problem was caused by the old DCB disk driver.
  22.  
  23. YOUR NAME AND DEPT.  : 
  24.  
  25. (Check all that apply)
  26.  
  27.   (X)    This information was verified verbally.
  28.